Edutek Instrumentation Ambala, Haryana

Send SMS
Contact Us

Clean Air Systems

Fume Hoods

Fume Hoods

Fume Hoods ETC-72

Designed to contain and exhaust toxic, obnoxious, pungent smelling gasses to protect personnel and equipment in the laboratories. The fume hood comprise with international standard on fume handling systems. A motor driven dynamically balanced blower with minimal vibration and noise level creates negative pressure and sucks contaminated air from work area and throws the same in high-up atmosphere through ductings.

Fabricated out of thick Duro-board clad from outside in laminated sheet and inside finished in non-corrosive, chemical resistant Epoxy paint. An up & down sliding Sash made of Teakwood mounted in thick glass sheet and workable on weights & pulleys system counter balanced is provided. Fluorescent lighting is provided in the chamber. A gas tap and electric power plug also provided in addition to stainless steel wash basin and suitable water tap.

A work-bench with cupboard is provided to hold the hood at suitable level from ground :


Additional Information:

Laminar Air Flow Cabinets- Vertical

Laminar Air Flow Cabinets- Vertical

Laminar Air Flow Cabinet ETC-73

works on laminar flow principle involves double filtration of air through coarse Pre Filters (upto microns) and Hepa filters (down to 0.3 microns) for filtration of Biological & Particulate contaminants. A constant uni-directional air flows either Horizontally or Vertically, is drawn from atmosphere and passed through pre and Hepa filters on to the work surface. Fabricated out of reinforced pest and weather resistant Duro-board which is clad in from outside in laminated sheet and inner exposed areas are finished in Epoxy paint. Table top stainless steel sheet. Side panels are fixed and made of clear plexiglass. Front door is folding & made of clear plexiglass.

Prefilters:-

DOP tested as per Standard BS

2831 with efficiency 90% down to 5

microns. Made of Washable synthetic material.

Hepa Filters:-

Made of Microglass fibre with corrugated aluminium foil separators. DOP tested as per US Standard 209B. Efficiency99.97% down to 0.3 microns.

Blower Units:-

Assembly of AU or equivalent motor workable on 220V AC 50Hzsingle phase, dynamically balanced blowers making the unit least vibrant with minimum noise level.

Features:
-
 Sizes are Available: 
 
ALSO AVAILABLE IN MILD STEEL/ STAINLESS STEEL
BODYK-System:-


The K-System encompasses the specialist requirement of ocyte, and embryo handling during procedures in both animal and human reproduction. The K-system is often built into a Laminar Flow Cabinet. The utensils are warmed by the heating of part of the table plate of the cabinet.

The transmitted light source and the regulation transformer for the stereo microscope are located under the stainless steel table plate, with a window for transmitted light built into the table plate.

Advantages of the K-System:-


Additional Information:

Laminar Air Flow Cabinets- Horizontal

Laminar Air Flow Cabinets- Horizontal

Laminar Air Flow Cabinets ETC-73A

Laminar Air Flow Cabinets
works on laminar flow principle involves double filtration of air through coarse Pre Filters (upto 5 microns) and Hepa filters (down to 0.3 microns) for filtration of Biological & Particulate contaminants. A constant uni-directional air flows either Horizontally or Vertically, is drawn from atmosphere and passed through pre and Hepa filters on to the work surface. Fabricated out of reinforced pest and weather resistant Duro-board which is clad in from outside in laminated sheet and inner exposed areas are finished in Epoxy paint. Table top stainless steel sheet. Side panels are fixed and made of clear plexiglass. Front door is folding & made of clear plexiglass.

Prefilters:-

DOP tested as per Standard BS: 2831 with efficiency 90% down to 5microns. Made of Washable synthetic material.

Hepa Filters:-

Made of Microglass fibre with corrugated aluminium foil separators. DOP tested as per US Standard 209B. Efficiency 99.97% down to0.3 microns.

Blower Units:-

Assembly of AU or equivalent motor workable on 220V AC 50Hzsingle phase, dynamically balanced blowers making the unit least vibrant with minimum noise level.

Features:
-
K-System:-

The K-System encompasses the specialist requirement of ocyte, and embryo handling during procedures in both animal and human reproduction. The K-system is often built into a Laminar Flow Cabinet. The utensils are warmed by the heating of part of the table plate of the cabinet.

The transmitted light source and the regulation transformer for the stereo microscope are located under the stainless steel table plate, with a window for transmitted light built into the table plate.

Advantages of the K-System:-

Available in following sizes :-
ALSO AVAILABLE IN MILD STEEL/STAINLESS STEEL BODY

Additional Information:

Laminar Air Flow Cabinet (SS)

Laminar Air Flow Cabinet (SS)

Laminar Air Flow Cabinet ( Stainless Steel) ETC-73C
Available in following sizes :-

Additional Information:

Bio Safe Biological Safety Cabinet

Bio Safe Biological Safety Cabinet

Bio Safe Biological Safety Cabinet ETC-74

These Class I safety cabinet provide protection for the operator and the environment, with inward airflow away from the operator. Air is filtered before release to the atmosphere.

Negative pressure is maintained within the cabinet, which is suitable for work where no product protection is required.
These cabinets are self contained 100% exhaust containment enclosures. Air from the work zone passes through a two-stage, high efficiency filter system before being exhausted to the room/atmosphere. These cabinets may be installed on standard laboratory benches or on optional support stands.

Personnel and environment protection is provided by inward flow of room air at the work area and high-efficiency particulate air (HEPA) filtration of exhaust air. The inward airflow sweeps aerosols generated during the work process away from the operator into the filter system. A pre-filter protects the HEPA filter from large particles, and the HEPA filter removes particulate contaminates down to sub-micron size from the exhaust air.
Supplied complete as above, with cord and plug, suitable to work on 220V single phase, 50Hz, AC supply.

Available in following sizes
:-
Work area: 

Additional Information:

Portable Tissue Culture Rack

Portable Tissue Culture Rack

Portable Tissue Culture Rack ETC-77

A high quality of tissue culture rack with following features:


Available shelves:-


Additional Information:

Tissue Culture Hood

Tissue Culture Hood

Tissue Culture Hood  ETC-75

Tissue Culture Hood/Aseptic Cabinet is an elegant equipment with overall dimensions 1220 x 610 x 610 mm having front horizontal swing door opening of 1050 x 405 mm (frame) fitted with transparent plexiglass. Complete with fluorescent lighting and germicidal ultra violet tube.


Additional Information:

Innoculation Hood

Innoculation Hood
Inoculation Hood ETC-75A
Inoculation Hood is fabricated out of pest and weather resistant Duro-board or mild steel sheet. Wood construction clad in laminated sheet from outside and inner exposed parts painted with Epoxy paint. The mild steel model is enamel painted.

Provided with rectangular, tight covered opening on one side for putting the material in the chamber and two covered round openings in front for handling of the material. A clear Acrylic fixed window in front provided for observation. Complete with fluorescent lighting and germicidal Ultra Violet (UV) tube.

Chamber Sizes:-


Additional Information:

Dehumidifiers

Dehumidifiers

Dehumidifier ETC-76

Dehumidifiers are designed to remove excess moisture from atmosphere when manufacturing activities of tablets, capsules and air accuracy is required. Humidity can be brought down to 30% RH with accuracy of ±3% RH.

Capacity:-


Additional Information:

Digital Laminar Flow Cabinet

Digital Laminar Flow Cabinet

Laminar Air Flow Cabinet ETC-73B


Additional Information:

Multiplate Clutch Model

Multiplate Clutch Model
Multiplate Clutch

A properly constructed all metallic model mounted on metal base with handle drive arrangement.

Additional Information:
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Clean Air Systems ?

    country-ico

    We will contact you soon !

    Aditiya Kumar

    (Manager)

    Edutek Instrumentation

    Inderpuri, Ambala, Haryana, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us